Silicon Tracker Software |
|
|
Dead Strip/Beetle/ReadoutSector Definitions
OK
- Strip is OK
- enum value is 0
Open
- Strip is interupted
- If the interupt is on the sensor closest to the hybrid no
signal can be seen.
- If it is a later sensor some signal may be seen
- enum value is 1
Short
- Two adjacent strips are shorted
- Signal will be seen, but with worse S/N and resolution
- enum value is 2
Pinhole
- Between implant and Al on the sensor
- Strip works fine before irradiation
- When irradiated dies as leakage current increases
- enum value is 3
ReadoutProblems
- Channel is not readout [digitizer board or tell1 problem]
- enum value is 4
NotBonded
- The channel is not bonded to the Beetle
- enum value is 5
LowGain
- Channel gives low signal
- enum value is 6
Noisy
- Channel has large noise
- enum value is 7
OtherFault
- Strip is dead for unknown reasons
- enum value is 9
Dead
- As a door-nail
- enum value is 10
Last modified: Thursday 17th 2008f July 2008, 17:29